The boiler appeared structurally sound on hydraulic test at 200psi although with several pinhole leaks on the foundation ring and one on the outer wrapper - all were dry under steam.
The chassis has wear to axleboxes and motionwork - it still actually runs quite nicely if you can put up with the clanking!
| gauge | 7 1/4 inch gauge |
| length/inches | 50 |
| width/inches | 15 |
| height/inches | 21 |
| weight/kg | 160 |
| wheel material | cast iron |
| axlebox type | plain bearing |
| cylinder material | cast iron |
| valve type | slide |
| valve gear | Walschaerts |
| reverser type | pole |
| injector(s) | 1 |
| superheater(s) | 3 |
| superheater type | flue tube |
| fusible plug | no |
| safety valve(s) | 2 |
| safety valve type | spring |
| mechanical pump | 1 |
| whistle | yes |